GLASS CONDUCTIVITY CELL K=0.1 MINI DIN CONNECTOR

Cells - Electrodes, Conductivity & Salt Testing, EDT

The E8075 Glass Conductivity Cell is for dip applications where the sample conductivity is low and the standard E8071 general purpose conductivity cell does not have the required sensitivity.

Typical applications could range from checking the quality of de-ionized or distilled water to sensitive analysis of ecological water sources.

The 12mm glass body has two internal active platinum electrodes in close proximity which have to be submerged in the samples to a minimum depth of around 2cm.

The E8075 Conductivity cell is suitable for use with the Series 4 QP481 and QP458 conductivity meters only and contains a temperature sensor to enable all readings to be temperature compensated (ATC). Calibration solutions are available and the recommendation for general purpose cells (K=1)is to calibrate using a 1413uS/cm standard such as EDT A3052and A3053.

Temperature reading and compensation range is 0-50 degrees centigrade. For general analysis above 500uS/cm use a K=1 cell (E8071). For process measurements or where the use of glass is not acceptable EDT manufacture a complete range of Conductivity cells to suit most applications.

GLASS CONDUCTIVITY CELL K=0.1 MINI DIN CONNECTOR

The E8075 Glass Conductivity Cell is for dip applications where the sample conductivity is low and the standard E8071 general purpose conductivity cell does not have the required sensitivity.

Typical applications could range from checking the quality of de-ionized or distilled water to sensitive analysis of ecological water sources.

The 12mm glass body has two internal active platinum electrodes in close proximity which have to be submerged in the samples to a minimum depth of around 2cm.

The E8075 Conductivity cell is suitable for use with the Series 4 QP481 and QP458 conductivity meters only and contains a temperature sensor to enable all readings to be temperature compensated (ATC). Calibration solutions are available and the recommendation for general purpose cells (K=1)is to calibrate using a 1413uS/cm standard such as EDT A3052and A3053.

Temperature reading and compensation range is 0-50 degrees centigrade. For general analysis above 500uS/cm use a K=1 cell (E8071). For process measurements or where the use of glass is not acceptable EDT manufacture a complete range of Conductivity cells to suit most applications.